Vw jetta 2017 repair manual torrent. SurgiStat Low-Power Electrosurgical Generator Service Manual. Accepts cables or adapters equipped with standard (Bovie™* #12) active plugs.
Ismael Cordero Electrosurgery is used routinely in eye surgery to cut, coagulate, dissect, fulgurate, ablate and shrink tissue. High frequency (100 kilohertz to 5 megahertz), alternating electric current at various voltages (200–10,000 Volts) is passed through tissue to generate heat. An electrosurgical unit (ESU) consists of a generator and a handpiece with one or more electrodes. The device is controlled using a switch on the handpiece or a foot switch. Electrosurgical generators can produce a variety of electrical waveforms. As these waveforms change, so do the corresponding tissue effects. In bipolar electrosurgery , both the active electrode and return electrode functions are performed at the site of surgery.
The two tips of the forceps perform the active and return electrode functions. Only the tissue grasped in the forceps is included in the electrical circuit. Because the return function is performed by one tip of the forceps, no patient return electrode is needed. Bipolar electrosurgery operates regardless of the medium in which it is used, permitting coagulation in a fluid environment – a great advantage when attempting to coagulate in a wet field.
As a result, bipolar electrosurgery is often referred to as ‘wet field’ cautery. In monopolar electrosurgery , the active electrode is placed at the surgical site.
The patient return electrode (also known as a ‘dispersive pad’ is placed somewhere else on the patient's body. The current passes through the patient as it completes the circuit from the active electrode to the patient return electrode. The function of the patient return electrode is to remove current from the patient safely. A return electrode burn will occur if the heat produced, over time, is not safely dissipated by the size or conductivity of the patient return electrode.
Modern electrosurgical machines have built-in safety features to prevent burns from occurring due to poor contact between the patient and the return electrode when using the monopolar mode. Often, the term ‘electrocautery’ is incorrectly used to describe electrosurgery. Electrocautery refers to direct current (electrons flowing in one direction) whereas electrosurgery uses alternating current. In electrosurgery, the patient is included in the circuit and current enters the patient's body.
During electrocautery, current does not enter the patient's body. Instead, current flows through a heating element, which burns the tissue by direct transfer of heat. Electrocautery or, more precisely, thermocautery units are usually portable battery powered devices that can be either disposable or reusable. Choose a location for the return electrode/dispersive pad that is as close to the operative site as possible, clean and dry, well vascularised, and over a large muscle mass.
Avoid bony prominences, adipose tissue, scar tissue, skin over implanted metal prostheses, hairy surfaces, and pressure points. If necessary, shave very hairy skin at the dispersive pad site. Make sure that conductive gel is moist and uniformly spread all over the contact area and that the dispersive pad achieves uniform contact with the patient's skin.
Specifications. Pre-Set buttons to save 10 physician settings. Duty Cycle: 300 watt @ 300 ohms. Two year warranty Dimensions and Weight:. Width: 31.1 cm (12.25 in.). Height: 15.3 cm (6.00 in.).
Depth: 41.3 cm (16.25 in.). Weight.