CT-80 - Literature CT-80 Product Brochure Category: Brochures Description: Sales brochure that explains an overview of features, options and basic technical specifications. Last Updated: June 16, 2009 CT-80 Instruction Manual Category: Manuals Description: Instruction manual that gives an overview of operating procedures for the CT-80. Last Updated: June 16, 2009 CT-80 Parts List Category: Technical Documentation Description: Parts list for CT-80. Last Updated: June 16, 2009 CT-80 Troubleshooting Guide Category: Technical Documentation Description: Troubleshooting guide for the CT-80. Last Updated: September 25, 2008 Topcon Medical Systems, Inc.
A TOP 0ual ty Easy T0 U88 SLR 'I8 20-fl3.5lult'rctd lmlaee. FC 11 q mp ' Q Full Manual Override, Shutter Lock “wr ':1' '5' “'1 '°''= 'M W. Mrteliellalerr1tesaboutlhe500 1050-'4 Fllllfl CT Iilb ' H - -%'.5. S0 l e-n-nth » rnm' and _ rh sin“ muons '5 5°79' Y 3 “ 93 1359': 3 'H '_ FvR“Mm Se 1 TOPCON Auto Til.
111 Bauer Drive Oakland, NJ 07436 G: 800.223.1130 P: 201.599.5100 F: 201.599.5250 Support: 866.922.6278 © 2018 Topcon Corporation.
Summary of Contents of user manual for Topcon CT-80. INSTRUCTION MANUAL COMPUTERIZED TONOMETER CT-80. INTRODUCTION Thank you for purchasing the TOPCON Computer- ized Tonometer CT-80. (To get the best use from the instrument. DISPLAY FOR SAFE USE In order to encourage the safe use of the product and prevent any danger to the. SAFETY CAUTIONS WARNING Icons Prevention item Page To avoid electrical shock, do not open the instrument. Refer all servicing to.
SAFETY CAUTIONS CAUTION Icon Prevention item Page To avoid potential injury, hold the instrument in the proper position. USAGE AND MAINTENANCE PURPOSE This tonometer “CT-80” is a precision electrical device for medical use that must be used under. WARNING INDICATIONS AND POSITIONS To ensure the safe usage of this equipment, precaution indications are provided. Abide by the following. CONTENT Introduction 1 INDIVIDUAL OPERATIONS Display for Safe Use 2 How to Print Out Measurement Values 42 Safety Cautions 3. COMPONENTS MAIN BODY COMPONENTS Measuring head TV Monitor Measuring switch Control lever Clamping knob Safety stopper knob Power lamp Control.
CONTROL PANEL COMPONENTS Clear switch Air check switch Select switch Print switch Auto/Manual switch Down switch Range switch Menu switch. MONITOR SCREEN COMPONENTS Measurement Screen (Auto mode, alignment) Target eye Measurement mode Outer alignment mark Measuring range Alignment bar Alignment. CONTENTS OF PRINTER OUTPUT Bar code Equipment No. Time/Date display Measured eye pressure Average eye.
STANDARD ACCESSORIES The following are the standard accessories. The figures in parentheses are the quantities. Please check to see that. PREPARATIONS HOW TO INSTALL THE INSTRUMENT Before carrying the instrument, be sure to affix it firmly by turning the fixing. HOW TO CONNECT THE POWER CABLE To avoid electrical shock, do not handle the power plug CAUTION with wet fingers.
INITIAL SETTINGS During the initial setting, date, time, operating time of the power save function, RS- 232C, mode of average. Time/Date Setting Example of operation: Illustrations show time setting. 1 Press on the control panel to get the Menu screen. 5 Press, of the control panel, renew figures and press MEASUREMENT SWITCH. The renewed figures are inputted. 5 ↔ 10 ↔ 20 ↔ 30 ↔ 60 4 Press MEASUREMENT SWITCH. The Menu screen is displayed.
3 Press, on the control panel, move the cursor to “EQUIPMENT” and press MEASUREMENT SWITCH. Setting The Average Value Mode The average value display of the measurement values can be selected from integer and decimal. 15: The average value is displayed as an integer (by rounding fractions to the nearest whole number). 4 Press MEASUREMENT SWITCH. The Menu screen returns. Message Input You can add a brief message to the.
■: A space for 1 character (Use this to delete a character, too.) STEP: The blinking icon. 2 Slide the paper roll onto the paper shaft, paying attention to the direction of unwind- ing, and pull. 7 Return the paper retainer lever back to its original position. 8 Reset the printer cover, holding the top of. Manual Setting 1 Press the printer cover with your thumb, slide it aside and remove. 2 Slide the paper roll. 5 Insert the paper straight into the printer along the paper guide.
6 Further insert the paper and draw out. 8 Set the printer cover, holding the top of the paper outside. If the paper is jammed, turn the. BASIC OPERATIONS PREPARATIONS BEFORE MEASUREMENT Turn ON the Power 1 Make sure the power cable is connected. For connection, see. If “NG (+)” or “NG (-)” is displayed, an anomaly has occurred.
Turn OFF the POWER SWITCH, and. 5 Adjust the height of the chinrest, by operating the chinrest handle, so that the tail of the patient's. 4 When the measuring nozzle reaches a position 8∼10mm from the cornea, release the safety stopper knob. MEASUREMENT UNDER AUTO MODE.
Adjust the height of the automatic instrument table so that correct measurement values can be. Alignment and Measurement It is recommended that you do intraocular pressure measure- ments several times. Since the intraocular pressure varies. 1 Hold the control lever and pull the machine body towards the operator.
2 Move the control lever in. 5 Move the machine body in directions as needed in order to get the alignment dot within the inner. Reference position 7 After the alignment bar is displayed, push the machine body out a little bit more. Display of Measurement Values Measurement values are displayed on the monitor screen for up to three measure- ments. 1 Hold the control lever and pull the machine body towards the operator. 2 Move the control lever in. 6 Holding the alignment dot within the inner alignment mark, slightly push the machine body toward the patient.
DELETING MEASUREMENT VALUES 1 Press on the control panel. All the measurement values of the right and left eyes are. INDIVIDUAL OPERATIONS HOW TO PRINT OUT MEASUREMENT VALUES. To avoid printer problems due to paper jams, do not feed. 3 Hold the paper and pull it diagonally to cut. MEMO. To avoid paper jams, cut the paper.
INPUT/OUTPUT VIA RS-232C Output via RS-232C This machine can output data via the RS-232C interface to a personal computer. 2017 slk 55 amg. BEFORE REQUESTING SERVICE CHECKING OPERATIONS Air Check If a problem is suspected, do an air check. If the result is. REFERENCE OPTIONAL ACCESSORIES Automatic instrument table AIT-20 and Table Board Driven by electric power, it can change the height of. RS-232C COMMUNICATION SPECIFICATIONS Connector Types Input terminal: DIN 8-pin (TSC08, Hoshiden) Output terminal: DSUB 9-pin (DE-9S-N, JAE) I/O Terminal Pin. Transmission Formula Mode 1, 2, 3 Synchronization Non-synchronous Communication speed 2400/9600 bps Start bit 1 bit Stop bit 2 bit.
Communication format Mode 2: Model name, Type No. 10 byte Time/Date 19 byte Measurement value (right or left eye). Data Receiving Patient ID data 13 byte (Example) or or Setting RS-232C Communication Conditions In the Menu screen. ⋅ Communication format Format: OFF, MODE 1, MODE 2, MODE 3, MODE 4, (FORMAT) STD 1 (For shipment, “OFF” is. MAINTENANCE AND CHECKING ACCURACY MAINTENANCE Cleaning the Measuring Window Glass.
To secure auto alignment and correct measurement values, clean. Cleaning the Window Glass inside the Nozzle. When the window glass inside the nozzle becomes stained, it makes the. Daily Maintenance. This machine must be kept free of dust; apply the measuring window cap and dust cover when. Paper Jam in Printer. If paper is jammed inside the printer, printing is not complete.
MEMO Attempts to forcibly. 3 Replace the fuse with the attached fuse. Replacing the Fuse 4 Press the fuse holder with a screwdriver.
When calling please give us the following infor- mation about your unit: ⋅ Machine type: CT-80 ⋅ Manufacturing No. COMPUTERIZED TONOMETER CT-80 TOPCON AMERICA CORPORATION CORPORATE OFFICE:37 West Century Road, Paramus, New Jersey 07652, U.S.A. Phone: 201-261-9450 Fax.